How to connect the 10" AUO G104SN02-V2 LVDS display to the phyBOARD-Mira i.MX6
The following is a guide for how to connect up PHYTEC's 10" LVDS display and resistive touch solution to the phyBOARD-Mira i.MX6.
Targeted Hardware
phyCORE-i.MX6, phyBOARD-Mira i.MX6
Targeted Software
phyBOARD-Mira i.MX6 PD15.2.0
Date
2/25/2016
This optional add on includes the following components:
10" LVDS Display (AUO G104SN02-V2) with resistive touch
LVDS display cable
LCD backlight and power cable
4-wire touch cable
Step-by-step guide
Connect the LVDS display cable between the display and connector X9 on the phyBOARD-Mira.
Connect the LCD backlight and power cable between the display and connector X8.
Connect the 4-wire touch cable between the display and X21.
Note
When connecting the 4-wire touch cable please note the location of the yellow wire to determine the location of pin 1.
Turn the phyBOARD-Mira and display so it is face up. It should look like the following.
The BSP has already been configured to support the display but it must be enabled as an expansion in Barebox. To activate the display enter the following in Barebox. See the phyBOARD-Mira i.MX6 Quickstart for more information.
edit /env/config-expansions
CODE
Add the following line.
. /env/expansions/imx6qdl-mira-enable-lvds # Enable for 10" LVDS Display AUO G104SN02-V2 with resistive touch
CODE
Save and exit using CTRL+D
Restart the board
On the first boot a touch screen calibration is recommended. To run this the default Qt application must be stopped. After calibration it can be restarted.